Bug #18395

closed

Smart proxy - 1.14.1 - Windows 2008R2 - uninitialized constant error - DHCP

Added by Jack Watroba almost 8 years ago. Updated over 6 years ago.

Status:
Closed
Priority:
Normal
Assignee:
-
Category:
DHCP
Target version:
Difficulty:
Triaged:
Fixed in Releases:
Found in Releases:

Description

Smart Proxy 1.14.1 on Windows, when trying to build a new system, the DHCP smart proxy on Windows fails with this error:

E, [2017-02-03T16:34:47.664152 ] ERROR -- : uninitialized constant DhcpsApi::Win2012::Misc
Did you mean? DhcpsApi::Misc

Actions #1

Updated by Anonymous almost 8 years ago

Could you enable debug-level logging on smart-proxy and post the complete log of the failure please?

Actions #2

Updated by Anonymous almost 8 years ago

Is this happening when you are trying to get an automatic ip address suggestion? If so, this feature isn't available on Windows 2008, you'll need Windows 2012 and later.

Actions #3

Updated by The Foreman Bot almost 8 years ago

  • Status changed from New to Ready For Testing
  • Assignee set to Anonymous
  • Pull request https://github.com/theforeman/smart-proxy/pull/508 added
Actions #4

Updated by Jack Watroba almost 8 years ago

Dmitri Dolguikh wrote:

Is this happening when you are trying to get an automatic ip address suggestion? If so, this feature isn't available on Windows 2008, you'll need Windows 2012 and later.

Oh, yeah from the behavior it seems like it's when it's getting an IP suggestion, which has been working on 2008R2 up until this point. If it's no longer supported, I'll update. Thanks.

Actions #5

Updated by Dominic Cleal almost 8 years ago

  • Category set to DHCP
  • Translation missing: en.field_release set to 209
Actions #6

Updated by Anonymous almost 8 years ago

  • Status changed from Ready For Testing to Closed
  • % Done changed from 0 to 100