Project

General

Profile

Actions

BMC

This documentation was moved to: https://www.theforeman.org/manuals/1.16/index.html#4.3.3BMC

HP iLO 3 and higher support

To use foreman BMC support with ilo 3 and higher, the following iLO settings are required
  • an ilo user with administrator rights. Just giving the user "Virtual Power and Reset" rights does not seem to be enough
  • enable IPMI
    - Administration -> Access Settings -> Enable IPMI/DCMI over LAN on Port 623

after this you can verify access by running ipmitool:

ipmitool power status  -H <iLO ip-address> -U <user> -I lanplus
Password:
Chassis Power is on

Dell DRAC

To configure ipmi from commandline :

# ipmitool lan set 1 ipaddr your_ip
# ipmitool lan set 1 netmask your_netmask
# ipmitool lan set 1 defgw ipaddr your_default_gw
# ipmitool lan set 1 access on

# ipmitool user set name 3 foreman
# ipmitool user set password 3 your_password
# ipmitool channel setaccess 1 3 callin=on ipmi=on link=on privilege=4
# ipmitool user enable 3

Updated by Lukas Zapletal about 7 years ago ยท 7 revisions