BMC¶
HP iLO 3 and higher support¶
To use foreman BMC support with ilo 3 and higher, the following iLO settings are required- an ilo user with administrator rights. Just giving the user "Virtual Power and Reset" rights does not seem to be enough
- enable IPMI
- Administration -> Access Settings -> Enable IPMI/DCMI over LAN on Port 623
after this you can verify access by running ipmitool:
ipmitool power status -H <iLO ip-address> -U <user> -I lanplus Password: Chassis Power is on
Dell DRAC¶
To configure ipmi from commandline :
# ipmitool lan set 1 ipaddr your_ip # ipmitool lan set 1 netmask your_netmask # ipmitool lan set 1 defgw ipaddr your_default_gw # ipmitool lan set 1 access on # ipmitool user set name 3 foreman # ipmitool user set password 3 your_password # ipmitool channel setaccess 1 3 callin=on ipmi=on link=on privilege=4 # ipmitool user enable 3