Project

General

Profile

BMC » History » Revision 6

Revision 5 (Felix Barbeira, 07/12/2013 06:48 AM) → Revision 6/7 (Felix Barbeira, 07/12/2013 07:39 AM)

h1. BMC 

 h2. HP iLO 3 and higher support 

 To use foreman BMC support with ilo 3 and higher, the following iLO settings are required 
 * an ilo user with administrator rights. Just giving the user "Virtual Power and Reset" rights does not seem to be enough 
 * enable IPMI 
  - Administration -> Access Settings -> Enable IPMI/DCMI over LAN on Port 623 

 after this you can verify access by running ipmitool: 
 <pre> 
 ipmitool power status    -H <iLO ip-address> -U <user> -I lanplus 
 Password: 
 Chassis Power is on 
 </pre> 

 h2. Dell DRAC 

 To configure ipmi from commandline : 

 <pre> 
 # ipmitool lan set 1 ipaddr your_ip 
 # ipmitool lan set 1 netmask your_netmask 
 # ipmitool lan set 1 defgw ipaddr your_default_gw 
 # ipmitool lan set 1 access on 

 # ipmitool user set name 3 foreman 
 # ipmitool user set password 3 your_password 
 # ipmitool channel setaccess 1 3 callin=on ipmi=on    link=on privilege=4 
 # ipmitool user enable 3 

 </pre>