Project

General

Profile

BMC » History » Version 4

Romain Vrignaud, 07/04/2013 10:01 AM

1 1 Sachar de Vries
h1. BMC
2 1 Sachar de Vries
3 1 Sachar de Vries
h2. HP iLO 3 and higher support
4 1 Sachar de Vries
5 1 Sachar de Vries
To use foreman BMC support with ilo 3 and higher, the following iLO settings are required
6 1 Sachar de Vries
* an ilo user with administrator rights. Just giving the user "Virtual Power and Reset" rights does not seem to be enough
7 1 Sachar de Vries
* enable IPMI
8 2 Sachar de Vries
 - Administration -> Access Settings -> Enable IPMI/DCMI over LAN on Port 623
9 1 Sachar de Vries
10 1 Sachar de Vries
after this you can verify access by running ipmitool:
11 1 Sachar de Vries
<pre>
12 1 Sachar de Vries
ipmitool power status  -H <iLO ip-address> -U <user> -I lanplus
13 1 Sachar de Vries
Password:
14 1 Sachar de Vries
Chassis Power is on
15 1 Sachar de Vries
</pre>
16 3 Romain Vrignaud
17 3 Romain Vrignaud
h2. Dell DRAC
18 3 Romain Vrignaud
19 3 Romain Vrignaud
To configure ipmi from commandline :
20 3 Romain Vrignaud
21 3 Romain Vrignaud
<pre>
22 3 Romain Vrignaud
# ipmitool lan set 1 ipaddr your_ip
23 3 Romain Vrignaud
# ipmitool lan set 1 netmask your_netmask
24 3 Romain Vrignaud
# ipmitool lan set 1 defgw ipaddr your_default_gw
25 3 Romain Vrignaud
# ipmitool lan set 1 access on
26 4 Romain Vrignaud
27 4 Romain Vrignaud
# ipmitool user set name 3 foreman
28 4 Romain Vrignaud
# ipmitool user set password 3 your_password
29 4 Romain Vrignaud
# ipmitool channel setaccess 1 3 callin=on ipmi=on  link=on privilege=4
30 4 Romain Vrignaud
31 3 Romain Vrignaud
</pre>