1 | 1 | Sachar de Vries | h1. BMC |
---|---|---|---|
2 | |||
3 | 7 | Lukas Zapletal | This documentation was moved to: https://www.theforeman.org/manuals/1.16/index.html#4.3.3BMC |
4 | |||
5 | 1 | Sachar de Vries | h2. HP iLO 3 and higher support |
6 | |||
7 | To use foreman BMC support with ilo 3 and higher, the following iLO settings are required |
||
8 | * an ilo user with administrator rights. Just giving the user "Virtual Power and Reset" rights does not seem to be enough |
||
9 | * enable IPMI |
||
10 | 2 | Sachar de Vries | - Administration -> Access Settings -> Enable IPMI/DCMI over LAN on Port 623 |
11 | 1 | Sachar de Vries | |
12 | after this you can verify access by running ipmitool: |
||
13 | <pre> |
||
14 | ipmitool power status -H <iLO ip-address> -U <user> -I lanplus |
||
15 | Password: |
||
16 | Chassis Power is on |
||
17 | </pre> |
||
18 | 3 | Romain Vrignaud | |
19 | h2. Dell DRAC |
||
20 | |||
21 | To configure ipmi from commandline : |
||
22 | |||
23 | <pre> |
||
24 | # ipmitool lan set 1 ipaddr your_ip |
||
25 | # ipmitool lan set 1 netmask your_netmask |
||
26 | # ipmitool lan set 1 defgw ipaddr your_default_gw |
||
27 | # ipmitool lan set 1 access on |
||
28 | 4 | Romain Vrignaud | |
29 | # ipmitool user set name 3 foreman |
||
30 | # ipmitool user set password 3 your_password |
||
31 | 6 | Felix Barbeira | # ipmitool channel setaccess 1 3 callin=on ipmi=on link=on privilege=4 |