Project

General

Profile

BMC » History » Version 7

Lukas Zapletal, 12/15/2017 12:10 PM
Moved BMC docs

1 1 Sachar de Vries
h1. BMC
2 1 Sachar de Vries
3 7 Lukas Zapletal
This documentation was moved to: https://www.theforeman.org/manuals/1.16/index.html#4.3.3BMC
4 7 Lukas Zapletal
5 1 Sachar de Vries
h2. HP iLO 3 and higher support
6 1 Sachar de Vries
7 1 Sachar de Vries
To use foreman BMC support with ilo 3 and higher, the following iLO settings are required
8 1 Sachar de Vries
* an ilo user with administrator rights. Just giving the user "Virtual Power and Reset" rights does not seem to be enough
9 1 Sachar de Vries
* enable IPMI
10 2 Sachar de Vries
 - Administration -> Access Settings -> Enable IPMI/DCMI over LAN on Port 623
11 1 Sachar de Vries
12 1 Sachar de Vries
after this you can verify access by running ipmitool:
13 1 Sachar de Vries
<pre>
14 1 Sachar de Vries
ipmitool power status  -H <iLO ip-address> -U <user> -I lanplus
15 1 Sachar de Vries
Password:
16 1 Sachar de Vries
Chassis Power is on
17 1 Sachar de Vries
</pre>
18 3 Romain Vrignaud
19 3 Romain Vrignaud
h2. Dell DRAC
20 3 Romain Vrignaud
21 3 Romain Vrignaud
To configure ipmi from commandline :
22 3 Romain Vrignaud
23 3 Romain Vrignaud
<pre>
24 3 Romain Vrignaud
# ipmitool lan set 1 ipaddr your_ip
25 3 Romain Vrignaud
# ipmitool lan set 1 netmask your_netmask
26 3 Romain Vrignaud
# ipmitool lan set 1 defgw ipaddr your_default_gw
27 3 Romain Vrignaud
# ipmitool lan set 1 access on
28 4 Romain Vrignaud
29 4 Romain Vrignaud
# ipmitool user set name 3 foreman
30 4 Romain Vrignaud
# ipmitool user set password 3 your_password
31 6 Felix Barbeira
# ipmitool channel setaccess 1 3 callin=on ipmi=on link=on privilege=4
32 5 Felix Barbeira
# ipmitool user enable 3
33 4 Romain Vrignaud
34 3 Romain Vrignaud
</pre>